EverActive UC4200
This is a new charger that occupies the podium in terms of versatility. In addition to its wide compatibility, it has also been equipped with advanced features, making it one of the best chargers in our range.
The UC4200 charger focuses on maximum compatibility - we can charge any Ni-MH rechargeable batteries in sizes: R6 AA, R03 AAA, R14 C, SC, R20 D and 9V batteries. In addition, the UC4200 also supports 3.6/3.7V Li-ion batteries, their high-voltage alternative - Li-HV, whose rated voltage is 3.85V and Li-FePO4 batteries. In the case of batteries based on Lithium, the charger will support such sizes as: 10440, 14500, 14650, 17500, 17670, 18350, 18500, 18650, 20700, 21700- also protected, 22650, 25500, 26500, 26650, 32650, 33600, 16340 R-CR123e . The maximum span of the sledge is up to 76mm, which will ensure the possibility of charging the increasingly popular 20700 and 21700 batteries in the version with electronic protection.
Li-ion/Li-HV and LiFePO4 batteries are charged very accurately using the CC/CV method with a termination of approx. 100mA. This guarantees full safety and full charging of any battery, even heavily degraded or low-capacity.
Ni-MH and 9V batteries are charged using the CC method (constant current) with very precise dV / PVD detection - charging is completed only after reaching the maximum voltage on the battery (the value of this voltage may be different for each battery).
In addition, the charger has been equipped with a number of protections such as:
- before recharging,
- against excessive discharge of cells,
- short-circuit / overload,
- Thermal
- against reverse polarity of cells.,
Wide compatibility is not the only advantage of this charger. Large, easy-to-read display with backlight, shows all the most important values in real time:
Key features: |
The charger will handle any cylindrical battery with a length of 32-76 mm and a maximum diameter of up to 33 mm.
The charger has double input voltage: 12V DC charger has integrated AC adapter - power cable included, car adapter available separately.
Produkt posiada oznaczenie CE.
- Li-ion batteries 3.6-3.7V, protected (with PCM/PCB)
- Li-ion batteries 3.6-3.7V, unprotected
- Li-ion batteries 3.8-3.85V, protected (with PCM/PCB)
- Li-ion batteries 3.8-3.85V, unprotected
- LiFePO4 Batteries
- Ni-MH batteries
- 6F22/9V batteries
- 12 V DC / 3000 mA
- AC 100-240V, 50-60Hz
- Processor-controlled CC/CV for Li-ion/Li-FePO4
- Processor-controlled CC with -ΔV/0ΔV/PVD for Ni-MH
- Charge
- Discharge
- Refresh/Cycle(Rozładowanie z odświeżaniem)
- Capacity measurement in mAh (Test)
- Measurement of internal resistance in mOhm (Quick test)
- Adjustable - 200mA / 2000mA per channel / slot for Li-ion / Li-FePO4(2000mA tylko dla kanałów 1 i 4)
- Adjustable - 200mA - 1000mA per channel/slot for Ni-MH
- Adjustable - 60mA /120mA for 9V batteries
- Li-ion 4.2V ±0,05V
- Li-HV 4.35V ±0,05V
- Li-FePO4 3.65V ±0.05V
- Ni-MH ~1.45V-1.55V dV/PVD
- 200mA /400mA(w zależności od wybranego prądu ładowania)
- Before reloading
- Before over-discharging cells
- Against overload / short circuit
- Overload
- Thermal - before overheating of batteries
- Before reverse polarity of cells
- UC-4200 Charger, 1m Power Cable, User Manual
- Li-ion batteries 3.6-3.7V, protected (with PCM/PCB)
- Li-ion batteries 3.6-3.7V, unprotected
- Li-ion batteries 3.8-3.85V, protected (with PCM/PCB)
- Li-ion batteries 3.8-3.85V, unprotected
- LiFePO4 Batteries
- Ni-MH batteries
- 6F22/9V batteries
- 12 V DC / 3000 mA
- AC 100-240V, 50-60Hz
- Processor-controlled CC/CV for Li-ion/Li-FePO4
- Processor-controlled CC with -ΔV/0ΔV/PVD for Ni-MH
- Charge
- Discharge
- Refresh/Cycle(Rozładowanie z odświeżaniem)
- Capacity measurement in mAh (Test)
- Measurement of internal resistance in mOhm (Quick test)
- Adjustable - 200mA / 2000mA per channel / slot for Li-ion / Li-FePO4(2000mA tylko dla kanałów 1 i 4)
- Adjustable - 200mA - 1000mA per channel/slot for Ni-MH
- Adjustable - 60mA /120mA for 9V batteries
- Li-ion 4.2V ±0,05V
- Li-HV 4.35V ±0,05V
- Li-FePO4 3.65V ±0.05V
- Ni-MH ~1.45V-1.55V dV/PVD
- 200mA /400mA(w zależności od wybranego prądu ładowania)
- Before reloading
- Before over-discharging cells
- Against overload / short circuit
- Overload
- Thermal - before overheating of batteries
- Before reverse polarity of cells
- UC-4200 Charger, 1m Power Cable, User Manual